No.258 IMPACT TESTER

JIS K7110、K7111-1、ASTM D256、D6110、ISO 179-1:2010、180

No.258 IMPACT TESTER

  • This pendulum type impact tester for plastic enables the operator to conduct both Charpy and Izod impact test just by changing the hammer and the anvil.
  • The tester can be attached with an optical rotary encoder, so that the impact data can be saved in a computer.

↑ DIGITAL/TP TYPE

Specification may change without notice.
Main Body Dimensions W500 × D350 × H850 mm
(Digital Touch Panel Spec : D+250mm, Curtain for Littler Control : W+520mm,
Safety Cover : W + 500mm × H + 275mm)
Main Body Weight 125 kg
(Digital Ver. : + 5kg, Curtain for Littler Control: + 5, Safety Cover: + 75 kg)
Power Source Digital Type without Safety Cover、 AC 100 V, 1-Phase, 3 A, 50/60 Hz
Digital Type with Safety Cover 、AC 100 V, 1-Phase, 5 A, 50/60 Hz
Accessories Assortment of Tools

※ It is listed in the below orders.
・258 JIS/ISO
・258 ASTM

JIS/ISO(←open)
Standard JIS/ISO
Test Method Charpy Impact Test Izod Impact Test
Base Standards JIS B7739:2011、ISO 13802:1999
Reference Standards JIS K7111-1:2012、ISO 179-1:2010 JIS K71110:1999、ISO 180:2000
Hammer Capacity
※1(J)
0.5, 1, 2, 4, 5 7.5, 15, 25※2 1, 2.75, 5.5, 11, 22
 Anvil JIS/ISO Charpy Anvil JIS/ISO/ASTM Izod Anvil
JIS/ISO Charpy Anvil Lift Necessary
Hammer Impact Point Setting Gauge JIS/ISO Hammer Impact Point Setting Gauge
Specimen Setting Gauge JIS/ISO Charpy Specimen Setting Gauge JIS/ISO  Izod Specimen Setting Gauge
Option Digital(Touch Panel, PC)Ver., Safety Cover(Full Cover),Curtain for Littler Control, Hammer Additional Weight,
Mini Printer (Thermal paper 10 rolls)※3, CSV Down load Tool(includes LAN cable)※4, Analog Scale & Pointer, Windows PC ※5, Additional Weight for Main Body ※6
Impact speed 2.9m/s 3.8m/s 3.5m/s
Lift-up Angle 150°
Hammer Edge R2±0.5mm、Angle:30±1° R0.8±0.2mm
Anvil Edge Radius R1±0.1mm
Anvil Supporting Edge R0.2±0.1mm
Anvil Supporting Length 62+0.05mm※7
Anvil-Edge Distance R22±0.2mm
※1 Custom Hammers can also be provided. kgf/cm Hammers are also available.
kinds of additional weights can be attached to a single hammer.
※2 50J Hammer is not available.
※3 Setting Gauge differs depending on the size of specimen thickness.
※4 Available when Digital Touch Panel Spec. is chosen.
※5 Required for the CSV Download Tool for the Digital Touch Panel Type spec.,
and Digital PC Type spec.
※6 Required when more than 15 J Hammer is used.
※7 This length is for JIS K7111-1. If other lengths are required, please let us know.
 
 
 
 
 
ASTM(←open)
 
Standard ASTM
Test Method Charpy Impact Test Izod Impact Test
Base Standards
Reference Standards ASTM D6110-10 ASTM D256-10
Hammer Capacity
※1(J)
2.7 or More
(Track Record: 0.5,1,2,4,5,7.5,15,25)
2.7
(Track Record: 1,2.75,5,11,22)
 Anvil ASTM Charpy Anvil JIS/ISO/ASTM Izod Anvil
JIS/ISO Charpy Anvil Lift
Hammer Impact Point Setting Gauge ASTM Hammer Impact Point Setting Gauge
Specimen Setting Gauge ASTM Charpy Specimen Setting Gauge ASTM  Izod Specimen Setting Gauge
Option Digital(Touch Panel, PC)Ver., Safety Cover(Full Cover),Curtain for Littler Control, Hammer Additional Weight,
Mini Printer (Thermal paper 10 rolls)※3, CSV Down load Tool(includes LAN cable)※4, Analog Scale & Pointer, Windows PC ※5, Additional Weight for Main Body ※6
Impact speed 3.46m/s 3.5m/s
Lift-up Angle 150°
Hammer Edge R3.17±0.12mm、Angle:45±2° R0.8±0.2mm
Anvil Edge Radius R3.17±0.12mm  
Anvil Supporting Edge R0.25±0.12mm
Anvil Supporting Length 101.6±0.5mm
Anvil-Edge Distance R22±0.05mm
 

※1 Custom Hammers can also be provided. kgf/cm Hammers are also available.
kinds of additional weights can be attached to a single hammer.
※2 50J Hammer is not available.
※3 Setting Gauge differs depending on the size of specimen thickness.
※4 Available when Digital Touch Panel Spec. is chosen.
※5 Required for the CSV Download Tool for the Digital Touch Panel Type spec.,
and Digital PC Type spec.
※6 Required when more than 15 J Hammer is used.
※7 This length is for JIS K7111-1. If other lengths are required, please let us know.

No.258-L IMPACT TESTER (WITH REFRIGERATING MACHINE)

JIS K7110、K7111-1、ASTM D256、D6110、ISO 179-1:2010、180

No.258-L IMPACT TESTER (WITH REFRIGERATING MACHINE)

  • This tester enables the operator to conduct the Charpy and Izod impact tests in a low temperature condition.
  • The low temperature chamber is double-doored and the inner door is equipped with working gloves so that the temperature inside the chamber is kept constant while the operator is attaching the test specimen.

Specification

Specifications are subject to change without notice.
Temperature Range -35 °C to 60 °C (Refrigerator)
Safety Device Hammer Setting Sensor (Interlock System on the Upper Door), Acrylic Safety Cover
Additional Specifications Refer to the below table
Option Software, Electric Hammer Release Device, Torque Adjustment Device (Only for Izod)
Power Source AC 200 V, 3-Phase, 40 A, 50/60 Hz
Dimensions/ Weight (Approx.) W1,100 × D1,160 × H1,760 mm, 450 kg
Specifications are subject to change without notice.
Test method Charpy Impact Tester Izod Impact Tester
Reference standards JIS K7111, ISO 179, ASTM D6110 JIS K7110, ISO 180, ASTM D256
Capacity 0.5, 1, 2, 4, 5, 7.5, 15, 25 J 1, 2.75, 5, 11, 22 J
Lift-up angle 150° 150°
Impact speed (m/s)* 2.9, 3.8 (3.46) 3.5 (3.46)
Striking Edge Angle* 30 ± 1° (45 ± 2°) 75° (-)
Striking Edge Radius (mm)* R2 ± 0.5 (R3.17 ± 0.12) R0.8 (R0.79 ± 0.12)
Anvil-Edge Distance (mm)* 22 ± 0.2 (22 ± 0.05)
Support Length (mm)* 62 + 0.5 (101.6 ± 0.5)
Accessories Specimen setting gauge, Block gauge, Torque wrench (Izod only) Specimen setting gauge, Block gauge, Torque wrench (Izod only)

*JIS/ISO Standard Value (ASTM Standard Value)

Inquiry Form

No.258-UTL IMPACT TESTER(WITH ULTRA LOW TEMP.REFRIGERATING MACHINE)

JIS K7110、K7111、ASTM D256、D6110、ISO 179、180

No.258-UTL IMPACT TESTER(WITH ULTRA LOW TEMP.REFRIGERATING MACHINE)

  • With the same funtionality, test method compatibility and options of No.258-L, No.248-UTL can lower the chamber temperature to exterme temperatures, as low as -50℃.

Specification

Specifications are subject to change without notice.
Temperature Range -50 °C to 60 °C (Refrigerator)
Safety Device Hammer Setting Sensor (Interlock System on the Upper Door), Acrylic Safety Cover
Additional Specifications Refer to the below table
Option Software, Electric Hammer Release Device, Torque Adjustment Device (Only for Izod)
Power Source AC 200 V, 3-Phase, 30 A, 50/60 Hz
Dimensions/ Weight (Approx. W1,670 × D1,480 × H2,130 mm, 710 kg
Specifications are subject to change without notice.
Test method Charpy Impact Tester Izod Impact Tester
Reference standards JIS K7111, ISO 179, ASTM D6110 JIS K7110, ISO 180, ASTM D256
Capacity 0.5, 1, 2, 4, 5, 7.5, 15, 25 J 1, 2.75, 5, 11, 22 J
Lift-up angle 150° 150°
Impact speed (m/s)* 2.9, 3.8 (3.46) 3.5 (3.46)
Striking Edge Angle* 30 ± 1° (45 ± 2°) 75° (-)
Striking Edge Radius (mm)* R2 ± 0.5 (R3.17 ± 0.12) R0.8 (R0.79 ± 0.12)
Anvil-Edge Distance (mm)* 22 ± 0.2 (22 ± 0.05)
Support Length (mm)* 62 + 0.5 (101.6 ± 0.5)
Accessories Specimen setting gauge, Block gauge, Torque wrench (Izod only) Specimen setting gauge, Block gauge, Torque wrench (Izod only)

*JIS/ISO Standard Value (ASTM Standard Value)

Inquiry Form

No.258-ZA IMPACT TESTER (FULL AUTOMATIC)

JIS K7110、K7111、ASTM D256、ISO 179、180

No.258-ZA IMPACT TESTER (FULL AUTOMATIC)

  • This is the fully automatic version of the IMPACT TESTER (Charpy and Izod).
  • A maximum of 210 impact tests can be continuously conducted just by setting the test specimen to the preparation cassette and inputting the test conditions in the computer software.
  • The test specimen will automatically come out from the preparation cassette which is located inside the low temperature chamber.
  • The test specimen will be impacted within 5 seconds after it comes out from the preparation cassette.

Specification

Specifications are subject to change without notice.
Temperature Range -40° 〜 80°(Refrigerator)
Hammer Capacity 0.5 to 25 J(Charpy),Capacity 1 to 7.5 J(Izod)
Automatic Lift-Up Device, Automatic Stop Device
Anvil Automatic Specimen Setting Device, Rejection Device for Tested Specimens
Test Specimens 70 pcs × 3 Cassettes (Total 210 pcs)
*When W10 × T4 × L80 mm, Automatic Cassette Changing Device
Software Windows Compatible
Option Hammer Height Adjustment Device (Only for Charpy), Hammer Changing Device (3 Capacities), Low Temperature Chamber, Constant Temperature & Humidity Chamber, Specimen Size Measuring Device, Collect Table for Tested Specimens
Power Source AC 200 V, 1-Phase, 10 A, 50/60 Hz
Low Temp. Chamber: AC 200 V, 3-Phase, 30 A, 50/60 Hz
Air Source 0.5 MPa or More
Dimensions/ Weight (Approx.) W1,150 × D1,050 × H1,950 mm, 700 kg

Inquiry Form

No.258-D Impact Tester(Digital/TP TYPE) OPERATION & MOTION VIDEO

Inquiry Form

    Catalog No. or Product Name*

    Request*

    Motive*

    Company Name*

    *Please input as much information as possible.

    Department

    First name*

    Last name*

    ZIP Code*

    Country*

    Address*

    Telephone Number*

    E-Mail Address*

    Description*